10/4C Solid Copper MC Stat® Aluminum THHN Insulation Interlocked Armored Cable
Allowable Ampacity for 10/4C Solid Copper MC Stat Aluminum THHN Insulation Interlocked Armored Cable: 100 Amps
Applications:
Branch circuit wiring is designed for use in patient care areas of hospitals, nursing homes, outpatient facilities, dental offices, clinics, and medical centers (excluding emergency, life safety, or critical care locations). It is also suitable for places of assembly, as defined by NEC Article 518, and can be installed under raised floors, above suspended ceilings, in environmental air-handling spaces, or in exposed or concealed dry locations. This wiring can be surface-mounted, fished, and used in any application requiring isolated or redundant grounding for normal or general-purpose power in healthcare settings, including patient care areas per NEC Article 517.
Also Known as:
AFC Cable, MC Cable, MC Stat Cable, Interlocked Armored, Interlocked Aluminum, Aluminum Cable, Aluminum Armor, MC Stat Lite, MCI-A Aluminum, 120/208V Cable
Construction:
• Armor: Interlocked Aluminum Strip (Light Green Striped)
• Conductors: Solid/Stranded Copper
• Conductor Insulation: Type THHN with protective polypropylene covering on each insulated conductor (no messy assembly tape)
• Neutral Conductor: White 120/208V, Grey for 277/480V
• Grounding: Two grounding means – (1) armor PLUS full-sized aluminum ground conductor, (2) Full-sized green insulated copper grounding conductor NEC 250.118(10)(b)
• Maximum Temperature Rating: 90°C (Dry)
• Maximum Voltage Rating: 600V
Features & Benefits:
• Interlocking Aluminum armor
• Green armor for easy cable identification in health care applications
• Armor plus full-sized aluminum ground wire is the equipment grounding means, • second equipment grounding means is the full-sized insulated copper grounding conductor
• MCI-A listed connectors required
• UL Classified for Through-Wall Penetrations
• Made in USA of US and/or imported materials
References & Ratings:
• UL 1569, UL 83, UL 1479, UL 1581, UL 2556, E80042
• Federal spec A-A–59544 (formerly J-C–30B)
• NEC 330, 300.22(C), 230.43, 250.118, 392, 396, 503, 530, 517, 518, 520, 645
• Permitted for use in Cable Trays
• May be surface mounted, fished, and/or embedded in plaster
• UL Classified 1, 2, and 3 hours through (Fire) penetration product, R–14141
• NEC 300.22(C) Environmental Air Handling Spaces
• Cable Tray Rated, install per NEC
• Meets all OSHA and HUD requirements
• Patent Pending
• Made in USA of US and/or imported materials
Specification:
• AWG Size: 10
• Number of Conductors: 4
• Copper Cond. Type: Solid
• Grounding Conductor AWG: 10 (Green)
• Bonding/Bond Cond. AWG: 8
• Cable Nominal O.D: 0.786 Inch
• Weight 1000ft: 301 Lbs
• (Black / Red / Blue / White) 250′ Coil Code: 5809-42-00
• (Black / Red / Blue / White) 1000′ Reel Code: 5809-60-00