100 Cable Gland PX2KPB Metal Armour Clamping Lead Sheathed Barrier Explosive Atmosphere
100 Cable Gland PX2KPB Metal Armour Clamping Lead Sheathed Barrier Explosive Atmosphere
Allowable Ampacity for 100 Cable Gland PX2KPB Metal Armour Clamping Lead Sheathed Barrier Explosive Atmosphere : 100 Amps
Also Known As:
Cable Gland, PX2KPB Gland, Armoured Gland, Atmosphere Gland, Lead Sheathed Gland, Metal Gland, Barrier Gland
Description :
• Effectively Earths / Grounds Lead Sheathed Cables
• Metal-to-metal Armour Clamping
• Direct & Remote Installation
• Compound Barrier Type Flameproof Seal
• Controlled Outer ‘Load Retention’ Seal
• Unique Ostg Prevents Overtightening
• Integral Protected Deluge Seal
• -60°C To +85°C
• Internationally Marked, Iecex & Atex
• Emc Tested
Construction :
• Design Specification : BS 6121:Part 1:1989, IEC 62444, EN 62444
• Mechanical Classifications : Impact = Level 8, Retention = Class D
• Enclosure Protection : IK10 To IEC 62262 (20 Joules) Brass & Stainless Steel Only
• Electrical Classifications : Category B (Category A when used with braid, tape or pliable wire armour cables)
• ATEX Certificate : SIRA13ATEX1072X, SIRA13ATEX4078X
• Code of Protection : II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da,II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb
• Compliance Standards : EN 60079-0,1,7,15,31
• IECEx Certificate : IECEx SIR 13.0027X, IECEx SIM 14.0008X
• Code of Protection : Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
• Compliance Standards : IEC 60079-0,1,7,15,31
• CCOE / PESO (India) Certificate : P333688
• NEPSI Certificate : GYJ13.1140X, GYJ13.1282X
• CCOE / PESO (India) Certificate : P333688
• INMETRO Approval : TUV 12.2073X
• RETIE Approval : 03866
• Marine Approvals : LRS: 01/00172, DNV: TAE000000Y, ABS: 14-LD234401A-4-PDA
• Ingress Protection Rating : IP66, IP67 & IP68
• Deluge Protection Compliance : DTS01 : 91
• Cable Gland Material : Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
• Seal Material : CMP SOLO LSF Halogen Free Thermoset Elastomer / Epoxy Barrier Compound
• Cable Type : Lead Sheathed & Single Wire Armour (LC/SWA), Lead Sheathed & Aluminium Wire Armour (LC/AWA), Lead Sheathed & Wire Braid Armour (LC/SWB)
• Armour Clamping : Detachable Compound Tube / Cone & AnyWay Universal Clamping Ring
• Sealing Technique : Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
• Sealing Area(s) : Inner Compound Barrier & Outer Sheath
• Optional Accessories : Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
• Optional Installation Tools : Spanners
Specification :
• Cable Gland Size: 100
• Available Entry Threads “C” (Alternate Metric Thread Lengths Available) Standard Metric: M100
• Available Entry Threads “C” (Alternate Metric Thread Lengths Available) Standard Thread Length (Metric) “E”: 24.0
• Available Entry Threads “C” (Alternate Metric Thread Lengths Available) Standard NPT: 4
• Available Entry Threads “C” (Alternate Metric Thread Lengths Available) Standard Thread Length (NPT) “E”: 44.0
• Available Entry Threads “C” (Alternate Metric Thread Lengths Available) Option NPT: 5
• Number of Cores: 200
• Diameter Over Conductors “A”: 85.6
• Lead Sheath Diameter “G” Min: 76.0
• Lead Sheath Diameter “G” Max: 88.1
• Overall Cable Diameter “B” Min: 86.1
• Overall Cable Diameter “B” Max: 101.4
• Armour Range Grooved Cone (X) Min: 0.8
• Armour Range Grooved Cone (X) Max: 1.6
• Armour Range Stepped Cone (W) Min: 3.15
• Armour Range Stepped Cone (W) Max: 4.0
• Across Flats “D” Max: 127.0
• Across Corners “D” Max: 139.7
• Protrusion Length “F”: 114.0
• Combined Ordering Reference(*Brass Metric) Size: 100
• Combined Ordering Reference (*Brass Metric) Type: PX2KPB
• Combined Ordering Reference (*Brass Metric) Ordering Suffix: 1RA
• Shroud: LSF33
• Cable Gland Weight: 11.275 Lbs