1000′ 1/0 AWG Cathodic Protection Cable HMWPE 75C 600V Copper Cable
[pdf] [/pdf] [short]
1/0 AWG Cathodic Protection Cable HMWPE 75c 600v Copper Cable
Allowable Ampacity for 1/0 AWG Cathodic Protection Cable HMWPE 75c 600v Copper Cable: 165 Amps
Applications:
HMWPE Cathodic Protection Cable is mostly used in cathodic protection systems as a direct burial DC feeder cable or a header cable. Some conventional applications of this electrical cable include wells, industrial structures submerged in water, pipelines, storage tanks, maritime transport, and direct burial structures. The electrical cable is rated at 600 volts.
Also Known As:
1/0 HMWPE Cathodic Protection Cable, 1/0 Cathodic Cable, 1/0 HMWPE Cable.
Standards:
- ASTM B-1, B-3, B-8, B-33, B-172, B-173 for soft drawn annealed copper conductors
- ASTM D-1248
- NEMA WC-5
- ICEA S-61-402 for High Molecular Weight Polyethylene (HMWPE)
- UL 83, UL 1581 and UL 2556
Construction:
Conductors:
The conductors are made from single-stranded bare copper. They meet UL83 and ASTM requirements.
Insulation:
The conductor is insulated with black, a High Molecular Weight Polyethylene HMWPE Type I. Types II, III, and IV are available on request.
Specifications:
- Size AWG: 1/0
- Weight: 0.413 lbs per ft
- Number of Strands: 19
- Outside Diameter: 0.62 inches
- Insulation: HMWPE
- Insulation Thickness: 0.125 inches
- Voltage: 600V
- Temp: 75°C
Manufacturer Equivalents |
|
Kalas : |
Black : 480016.91.001 |
Omni Cable : |
Black : M31/001CP |
[/short]
Applications:
Cathodic Protection Cable is used for direct earth burial DC feeder cable for cathodic protection systems, storage tanks, pipelines, wells, ocean vessels, and metallic structures buried or water submerged.
Standards:
2.1 ASTM B-1, B-3, B-8, B-33, B-172,and B-173 for soft drawn annealed copper conductors 2.2 ASTM D-1248, NEMA WC-5, ICEA S-61-402 for High Molecular Weight Polyethylene (HMWPE). 2.3 UL 83, UL 1581 and UL 2556
Conductors:
Single stranded copper conductors per UL83 and ASTM requirements.
Insulation:
The conductor shall be insulated with black, sunlight resistant polyethylene complying with the physical and electrical properties per ASTM D-1248, Type I, Class A thru D, Cat 4, and Grades E4-E5. Types II, III, and IV are available on request. The insulation shall be concentrically applied and the minimum at any point shall not be less than 90% of the specified average thickness. Rated at 75°C, 600 volts.
*Data provided on this page is subject to change based on different manufacturers variances.