1000′ 2-2-2 Ramapo Triplex Aluminum Conductor Underground Direct Burial 600V URD Online Sale

Original price was: $1,224.99.Current price is: $245.00.

SKU: US-6871395991706 Categories: ,

1000′ 2-2-2 Ramapo Triplex Aluminum Conductor Underground Direct Burial 600V URD
[pdf] [/pdf]

2-2-2 Ramapo Triplex Aluminum Conductor Underground Direct Burial 600V URD

Allowable Ampacity for 2-2-2 Ramapo Triplex Aluminum Conductor 600V URD direct burial: 165 Amps

Allowable Ampacity for 2-2-2 Ramapo Triplex Aluminum Conductor 600V URD in duct: 120 Amps

Applications:

The Aluminum 600V URD is designed to serve in the secondary distribution circuits for power. In these secondary circuits, the electrical cable is installed in duct or direct burial applications. Due to its versatility, conductor strength, and insulation integrity, it works well for these outdoor applications. It is also used in wet and dry places since the electrical cable has a maximum operating temperature of 90°C. The triplex wire for sale is also designed to provide an option of pre-pulling into ducts.

Also Known As:

2-2-2 ramapo aluminum urd cable, 2-2-2 ramapo urd direct burial cable, 2-2-2 ramapo three conductor cable, 2-2-2 ramapo tri plex wire, triplex cable, 2-2-2 ramapo triplex aluminum underground wire, 2-2-2 ramapo 3 conductor power cable, aluminum triplex, 2-2-2 ramapo underground triplex, 2-2-2 ramapo triplex underground cable, 2-2-2 ramapo triplex wire underground, 2-2-2 ramapo direct burial triplex, 2-2-2 ramapo triplex conductor, 2-2-2 ramapo direct burial electrical cable, 2-2-2 ramapo direct burial power cable, 2-2-2 ramapo aluminum direct burial cable.

Standards:

  • ASTM B-230

  • ASTM B-231

  • ASTM B-609

  • ASTM B-901

  • ICEA S-105-692

  • J-C- 30B Federal Specification

  • RUS accepted

Construction

Conductors:

Aluminum conductors used for this cable are designed in either concentric strand or in compressed series. The advantage with a compressed conductor is the reduced bulkiness. Compressed conductors are also stronger and tougher; the stranded conductors are highly flexible and tend to have lower electrical resistance. Stranded conductors therefore reduce power loss and are also easier to use in applications where flexibility is vital. Aluminum 600 V URD cable has three aluminum conductors.

Insulation:

Versatile insulation system made of cross linked black polyethylene material helps to secure the cable conductors. This insulation is water tight, repulsive to corrosive substances, resistant to oil, heat and flame. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions like direct burial installation.

Specifications:

    • Size AWG: 2

    • Stranding: 7

    • Insulation Thickness (mils): 60

    • Neutral Size AWG: 2

    • Single Phase Conductor Inches: 0.403

    • O.D. Inches:  0.874

    • Weight lbs./1000ft: 294 lbs

    • Ampacity: Direct burial: 165 Amps

    • Ampacity: In duct: 120 Amps

<!–


Application:

Aluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can provided pre-pulled into duct.

Conductors:

Aluminum 600V URD cable has a concentric strand or compressed 1350-H19 series aluminum conductor. Conductors are cabled together, with surface printing for identification. The neutral conductor has a yellow stripe.

Insulation:

Aluminum 600V URD cable has a black cross linked polyethylene (XLP) insulation.

Standards:

  • ASTM B-230 
  • ASTM B-231 
  • ASTM B-609 
  • ASTM B-901 
  • ICEA S-105-692 
  • Federal Specification J-C – 30B

–>