1000′ 23 AWG 4 Pairs Black CAT6 CMXF Direct Burial Gel-Filled Core LLDPE Jacket Cable
[pdf] [/pdf]
1000′ 23 AWG 4 Pairs Black CAT6 CMXF Direct Burial Gel-Filled Core LLDPE Jacket Cable
Description
CAT6 Shielded, 23 AWG Solid-Bare Copper Direct Burial, Gel-flooded core
FEATURES :
⦿ High-Performance Data Cable
⦿ 550 MHz Bandwidth, 10/100/1000 Base-T
⦿ CAT6 Shielded Twisted Pair
⦿ 23 AWG Solid Copper Conductors
⦿ Gel-Flooded Core, LLDPE Jacket
⦿ Easily Identified Color-Striped Pairs
⦿ Exceeds TIA/EIA-568C.2, ISO/IEC 11801
⦿ ETL-Listed, RoHS Compliant
⦿ 1000 FT Wooden Spool
Technical Data
⦿ Rated Temperature 70º C
⦿ Voltage Rating 60 V*
⦿ Flammabilty Test IEC-332-1
Conductor Solid Bare Copper
⦿ Size 23 AWG
Insulation PE
⦿ Average Thickness 0.0098 in. (0.248 mm)
⦿ Min. Point Thickness 0.0087 in. (0.222 mm)
⦿ Insulation Diameter 0.043 in. (1.08 mm ±0.01)
⦿ Twisted Pair Diameter 0.085 in. (2.16 mm ±0.02)
⦿ Insulation Rating 300 V*
Shielding Aluminum Foil
⦿ PE-Tape Yes
⦿ Drain Wire (Tinned Copper) 0.016 in. (0.40 mm)
Separator LDPE
⦿ Assembly Diameter 0.26 in. (6.60 mm)
Jacket LLDPE
⦿ Outer Diameter 0.32 in. (8.10 mm ±0.20)
⦿ Average Thickness 0.028 in. (0.70 mm)
⦿ Min. Point Thickness 0.025 in. (0.63 mm)
⦿ Gel Yes
⦿ Rip Cord Nylon
⦿ Color Black
Color of Pairs
⦿ Pair 1: Blue, White-Blue
⦿ Pair 2: Orange, White-Orange
⦿ Pair 3: Green, White-Green
⦿ Pair 4: Brown, White-Brown
Mechanical Characteristics
⦿ Test Object Jacket
⦿ Test Material LLDPE
⦿ Before Tensile Strength (Mpa) >=10.8
⦿ Aging Elongation (%) >=300
⦿ Aging Condition (ºCxhrs) 100×168
⦿ After Tensile Strength (Mpa) >=85% of unaged
⦿ Aging Elongation (%) >=50% of unaged
⦿ Cold Bend (-20±2º Cx4hrs) No Crack
Jacket Marking:
⦿ VERTICAL 4001453 cETLus VERIFIED F/UTP 4PR 23 AWG OUTDOOR
DIRECT BURIAL (FLOODED) UV LLDPE CAT6 550MHz ANSI/TIA-568.2-D
RoHS V1379P13254 XXXFT (SEQUENTIAL FOOT MARKERS ON JACKET)