1000′ 6-6-6 Erskine Triplex Aluminum Conductor Underground Direct Burial 600V URD Fashion

Original price was: $824.99.Current price is: $165.00.

SKU: US-6868851622042 Categories: ,

1000′ 6-6-6 Erskine Triplex Aluminum Conductor Underground Direct Burial 600V URD
[pdf] [/pdf]

[short]

6-6-6 Erskine Triplex Aluminum Conductor Underground Direct Burial 600V URD

Allowable Ampacity for 6-6-6 Erskine Triplex Aluminum Conductor 600V URD direct burial: 95 Amps

Allowable Ampacity for 6-6-6 Erskine Triplex Aluminum Conductor 600V URD in duct: 70 Amps

Applications:

The Aluminum 600V URD is designed to serve in the secondary distribution circuits for power. In these secondary circuits, the electrical cable is installed in duct or direct burial applications. Due to its versatility, conductor strength, and insulation integrity, it works well for these outdoor applications. It is also used in wet and dry places since the electrical cable has a maximum operating temperature of 90°C. The triplex wire for sale is also designed to provide an option of pre-pulling into ducts.

Also Known As:

6-6-6 erskine aluminum urd cable, 6-6-6 erskine urd direct burial cable, 6-6-6 erskine three conductor cable, 6-6-6 erskine tri plex wire, 6-6-6 erskine triplex cable, 6-6-6 erskine triplex aluminum underground wire, 6-6-6 erskine 3 conductor power cable, 6-6-6 erskine aluminum triplex, 6-6-6 erskine underground triplex, 6-6-6 erskine triplex underground cable, 6-6-6 erskine triplex wire underground, 6-6-6 erskine direct burial triplex, 6-6-6 erskine triplex conductor, 6-6-6 erskine direct burial electrical cable, 6-6-6 erskine direct burial power cable, 6-6-6 erskine aluminum direct burial cable.

Standards:

  • ASTM B-230

  • ASTM B-231

  • ASTM B-609

  • ASTM B-901

  • ICEA S-105-692

  • J-C- 30B Federal Specification

  • RUS accepted

Construction

Conductors:

Aluminum conductors used for this cable are designed in either concentric strand or in compressed series. The advantage with a compressed conductor is the reduced bulkiness. Compressed conductors are also stronger and tougher; the stranded conductors are highly flexible and tend to have lower electrical resistance. Stranded conductors therefore reduce power loss and are also easier to use in applications where flexibility is vital. Aluminum 600 V URD cable has three aluminum conductors.

Insulation:

Versatile insulation system made of cross linked black polyethylene material helps to secure the cable conductors. This insulation is water tight, repulsive to corrosive substances, resistant to oil, heat and flame. Cross linking a polyethylene helps to achieve an excellent strength that makes the material suitable for covering this cable used in harsh conditions like direct burial installation.

Specifications:

    • Size AWG: 6

    • Stranding: 7

    • Insulation Thickness (mils): 60

    • Neutral Size AWG: 6

    • Single Phase Conductor Inches: 0.299

    • O.D. Inches:  0.646

    • Weight lbs./1000ft: 143 lbs

    • Ampacity: Direct burial: 95 Amps

    • Ampacity: In duct: 70 Amps

[/short]


Application:

Aluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can provided pre-pulled into duct.

Conductors:

Aluminum 600V URD cable has a concentric strand or compressed 1350-H19 series aluminum conductor. Conductors are cabled together, with surface printing for identification. The neutral conductor has a yellow stripe.

Insulation:

Aluminum 600V URD cable has a black cross linked polyethylene (XLP) insulation.

Standards:

  • ASTM B-230 
  • ASTM B-231 
  • ASTM B-609 
  • ASTM B-901 
  • ICEA S-105-692 
  • Federal Specification J-C – 30B