16 AWG 12P Stranded BC Shield Individual Al Tape PE Blue PVC RE-2Y(St)Yv PiMF 300V Instrumentation Cable
[pdf] [/pdf]
16 AWG 12P Stranded BC Shield Individual Al Tape PE Blue PVC RE-2Y(St)Yv PiMF 300V Instrumentation Cable
Allowable Ampacity for 16 AWG 12P Stranded BC Shield Individual Al Tape PE Blue PVC RE-2Y(St)Yv PiMF 300V Instrumentation Cable: 100 Amps
About:
This type of cable is an instrumentation cable used primarily for transmitting signals or data in industrial applications. It’s designed to minimize electrical interference while ensuring stable and accurate communication.
Also Known As:
• PE Insulated PVC Sheathed Instrumentation Cable
• Aluminum Tape Shielded Instrumentation Cable
• Pair Instrumentation Cable
Application:
Instrumentation cables are used in data processing and process control and are suitable for fixed installations in damp locations, in open locations, in open spaces and for underground laying.
Standards:
• Typically, this cable meets international standards like IEC or ASTM, depending on its specific applications and construction.
• It is designed to be flame retardant, oil-resistant, and may have certain low-smoke zero-halogen (LSZH) properties based on the standards it adheres to.
Construction:
• Conductor: Stranded red copper conductor Cl. 2, acc. to IEC 60228, DIN VDE 0295
• Insulation: PE type 2YI1
• Colour cores: White-black, with black progressively numbered
• Stranding: Conductors twisted in pairs
• Screen: electrostatic screen of plastic and aluminium tape + tinned drain-wire
• Outer Sheath: Blue (RAL 5015) or black (RAL 9005) PVC type TM1, outer sheath reinforced
Features:
• Conductor Resistance: 0,5 mm²: max. 39,0 Ohm/km 1,3 mm²: max. 14,2 Ohm/km
• Insulation Resistance: min. 5 GOhm x km
• Mutual Capacitance: at 800 Hz core/core 0,5 mm : 75 nF/km core/core 1,3 mm : 100 nF/km
• Inductance: max. 0,75 mH/km
• Cross-talk attenuation: min 1,02 dB/kmat 60 kHz
Specifications:
• No. of pairs x cross section n x mm²: 12x2x1,3
• AWG no.: 16
• Outer-Ø ca.mm ± 10%: 21,4
• Copper Weight kg/km: 353
• Nominal Voltage: 300 V
• Test Voltage: core/core 2 kV, core/screen 1 kV
• Temperature Range: Fixed laying: – 40° C up to + 70° C, Flexible application: – 5° C up to + 70° C
• Min. bending radius: 7.5 x d
• Cable Weight approx. kg/km: 593
• Part Number: 47110CBX122M13