160-22-3032 1100 MCM 1C Aluminum Shield EPR 1/6 Neutral Okoguard Okoseal PVC 69KV URD Transmission Cable Fashion

Original price was: $4.99.Current price is: $2.00.

SKU: US-8213885288602 Categories: ,

160-22-3032 1100 MCM 1C Aluminum Shield EPR 1/6 Neutral Okoguard Okoseal PVC 69KV URD Transmission Cable

[pdf] [/pdf]

160-22-3032 1100 MCM 1C Aluminum Shield EPR 1/6 Neutral Okoguard Okoseal PVC 69KV URD Transmission Cable

Allowable Ampacity for 160-22-3032 1100 MCM 1C Aluminum Shield EPR 1/6 Neutral Okoguard Okoseal PVC 69KV URD Transmission Cable:100 Amps

About:

The “160-22-3032 1100 MCM 1C Bare Copper Shield EPR 1/6 Neutral Okoguard Okoseal PVC 69KV URD Transmission Cable” is designed for high-voltage underground power distribution, featuring a bare copper conductor, EPR insulation, partial neutral sizing, and a durable Okoseal PVC jacket, suitable for 69KV.

Also Known As:

1100 MCM 69KV URD Cable
Copper Shielded EPR URD Cable
High Voltage Okoguard Cable

Application:

 Okoguard-Okolene 69kV cables are for use as primary circuits in electrical utility and industry applications where they provide maximum circuit security and economical installation. Rated 105°C for continuous operating temperature. Okoguard 69kV cables may be installed in wet or dry locations indoors or outdoors (exposed to sunlight) in underground ducts, conduits or direct burial.

Standards:

ANSI/ICEA S-94-649 for concentric neutral cables.
 ASTM standards for copper, EPR, and PVC material properties.
 AEIC CS8 specifications for extruded dielectric shielded power cables.

Construction:

• Conductors: Uncoated copper sizes 250 through 1000 kcmil are compact round
strand per ASTM B496. Uncoated copper sizes larger than 1000 kcmil are compressed Class B strand per ASTM B3 and ASTM B8. Aluminum conductors are compressed Class B strand per ASTM B231 & B609.
• Conductor Screen: 
Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-108-720 and AEIC CS9.
 Insulation: Extruded Okoguard meets or exceeds the requirements of ICEA S-108-
720 and AEIC CS9.
• Insulation Screen: 
Extruded semiconducting EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-108-720 and AEIC CS9. Available with strippable or bonded screen.
• Concentric Conductor: 
Bare copper concentric neutral wires helically applied sized 1/3, 1/6 or 1/12 or based on fault current requirements. Optional shields include a combination of copper tape and wires or a longitudinal corrugated copper tape. A C-L-X armor covering is also ® available.
• Jacket: 
Black OKOLENE LLDPE with red extruded stripes that meets and exceeds
the requirements of ICEA S-108-720 and AEIC CS9. Optional jackets include FRPVC OKOSEAL , OKOLON TP-CPE , ® ® OKOCLEAR TP (TPPO-low smoke zero ® halogen) and when specified, a thermoset jacket or semi-conducting outer layer

Features:

 Triple tandem extruded, all EPR system.
 
Okoguard cables meet or exceed AEIC and ICEA standards.
 
Improved temperature rating. Okoguard insulation system has been tested and
qualified for operation at 105°C continuous and 140°C emergency operating
temperature.
 
250°C short circuit rating.
 
Excellent corona resistance.
 
Low dielectric constant and power factor.
 
Screens are clean stripping.
 
Exceptional resistance to “treeing”.
 
Moisture resistant.
 
Excellent resistance to most chemicals.

Specifications:

• Conductor Size AWG kcmil: 1100(61x)
• Conduit Size Inches (2):
5
Neutral Size: 1/6
Neutral Wires Num x AWG: 18×12
Nominal Dia. over Insulation (in.): 2.51
Nominal Dia. over Screen (in): 2.64

• Jacket Thickness (- mils): 140
Nominal OD (in.): 3.10

• Approx. Net Weight: 4692
• Ampacitiy  Duct Bank (1): 673
• Ampacitiy Direct Bury (1): 778
• Part Number: 160-22-3032