Sale!
,

160-23-3946 750 MCM 1C Aluminum Unshielded EPR Concentric BC 1/3 Neutral 15KV Okoguard URO Cable Online Sale

Original price was: $4.99.Current price is: $2.00.

SKU: US-8210955567258 Categories: ,

160-23-3946 750 MCM 1C Aluminum Unshielded EPR Concentric BC 1/3 Neutral 15KV Okoguard URO Cable

[pdf] [/pdf]

160-23-3946 750 MCM 1C Aluminum Unshielded EPR Concentric BC 1/3 Neutral 15KV Okoguard URO Cable

Allowable Ampacity for 160-23-3946 750 MCM 1C Aluminum Unshielded EPR Concentric BC 1/3 Neutral 15KV Okoguard URO Cable:100 Amps

About:

This is a medium voltage power cable with a voltage rating of 15KV, designed primarily for underground residential distribution (URO) systems. It features a single aluminum conductor, insulated with Ethylene Propylene Rubber (EPR), and includes a concentric bare copper neutral.

Also Known As:

750 MCM AWG Single Conductor Medium Voltage Cable
 15KV URO Aluminum Cable
 Unshielded EPR 15KV Cable

Application:

 Okoguard URO cables provide excellent circuit longevity in underground residential distribution systems. They can be buried direct or installed in underground ducts or conduits.

Standards:

 Complies with relevant IEEE standards for medium voltage power cables.
 Meets necessary ANSI specifications for installation and performance in underground residential distribution systems.
 Flame retardant, moisture, and chemical resistance standards are also typically met, adhering to industry requirements.

Construction:

• Central Conductor: Aluminum per ASTM B-609, Class B stranded per B-231.
• Conductor Screen:
 Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649 and AEIC CS8.
 Insulation: Extruded Okoguard meets or exceeds the requirements of ICEA S-94-649 for ethylene-propylene rubber and AEIC CS8.
• Insulation Screen:
 Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649 and AEIC CS8.
• Concentric Conductor: 
Bare copper wire

Features:

 Triple tandem extruded, all EPR system
 Okoguard cables meet or exceed ICEA standards.
 105°C continuous operating temperatures
 140°C emergency rating
 250°C short circuit rating
 Excellent corona resistance.
 Low dielectric constant and power factor.
 Screens are clean stripping.
 Exceptional resistance to “treeing”.
 Moisture resistant.
 Excellent resistance to most chemicals.
 Design Options: Additional conductor sizes Filled strand Copper central conductor Custom neutral sizes 100% Insulation Level
 Improved Temperature Rating. Okoguard insulation system has been tested and qualified for operation at 105°C continuous and 140°C emergency operating temperature.
 Minimum installation temperature of -40°C.
 Can be listed by UL as Type MV-90 on Special Orders.
 Cable print legend with sequential footage printed on insulation screen.

Specifications:

• Conductor Size AWG kcmil: 750(61x)
• Nominal Dia. Over Insulation (in): 1.49

• Insulation Screen Thickness (miles):
 40
• Nominal Dia. Over Insulation Screen (in): 1.59
• Copper Neutral, No. x AWG(1): 16x.0966
• Nominal O.D (In): 1.78
• Approx. Net Weight: 1895
• 90° C Ampacity Direct Burial (2): 570

• 90° C Ampacity Duct (2): 470
• 105° C Ampacity Direct Burial (2): 600
• 105° C Ampacity Duct (2): 510

• Part Number: 160-23-3946