Sale!
,

160-23-8052 1250 MCM 1C Aluminum Unshielded EPR Concentric 1/6 Neutral Okolene 445 46KV Okoguard URO-J Cable Online

Original price was: $4.99.Current price is: $2.00.

SKU: US-8220421488794 Categories: ,

160-23-8052 1250 MCM 1C Aluminum Unshielded EPR Concentric 1/6 Neutral Okolene 445 46KV Okoguard URO-J Cable

[pdf] [/pdf]

160-23-8052 1250 MCM 1C Aluminum Unshielded EPR Concentric 1/6 Neutral Okolene 445 46KV Okoguard URO-J Cable

Allowable Ampacity for 160-23-8052 1250 MCM 1C Aluminum Unshielded EPR Concentric 1/6 Neutral Okolene 445 46KV Okoguard URO-J Cable:100 Amps

About:

This is a high-voltage cable designed for power distribution, capable of handling up to 46 kV. The aluminum conductor makes it a lighter and often more economical choice compared to copper cables.

Also Known As:

This type of cable may also be referred to as a high-voltage, single conductor cable with enhanced insulation and jacketing materials.

Application:

It is typically used in power transmission and distribution networks, especially where high voltage and reliability are necessary. Common applications include connections between substations and primary overhead or underground distributions.

Standards:

The cable meets specific standards to ensure safety, reliability, and efficiency. These might include ANSI/NEMA WC standards or IEEE standards for insulated cables, particularly for electrical properties, fire resistance, and environmental resistance (e.g., IEEE 1202 for flame testing).

Construction:

• Conductor: Uncoated copper sizes 4/0 AWG through 1000 kcmil are compact round strand per ASTM B496. Uncoated copper sizes larger than 1000 kcmil are compressed Class B strand per ASTM B3 and ASTM B8. Aluminum per ASTM B609, compressed Class B strand per ASTM B231.
• Conductor Screen: Extruded semiconducting ethylene-propylene rubber meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.

 Insulation: Extruded Okoguard meets or ® exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Insulation Screen:
 Extruded semiconducting EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.
• Concentric Conductor: 
Bare copper concentric neutral wires helically applied.
 Jacket: Black OKOLENE LLDPE with red ® extruded stripes. Meets or exceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5 for polyethylene jackets.

Features:

 Triple tandem extruded, all EPR system.
 Okoguard cables meet or exceed ICEA standards.
 Improved temperature rating. Okoguard insulation system has been tested and qualified for operation at 105°C continuous and 140°C emergency operating temperature.
 250°C short circuit rating.
 Excellent corona resistance.
 Low dielectric constant and power factor.
 Screens are clean stripping.
 Exceptional resistance to “treeing”.
 Moisture resistant.
 Excellent resistance to most chemicals.
 CSA C68.5 listed, LTGG (-40°C), SR.

Specifications:

• Conductor Size AWG kcmil: 1250(91x)
• Neutral Size: 1/6

 Neutral Wires Num X AWG:
20×12
• Nominal Dia. Over Insulation (in): 2.21
• Nominal Dia. Over Screen (in): 2.35
• Jacket Thickness (miles): 80
• Nominal O.D (in): 2.68
• Approx. Net Weight: 3833 
• 90° C Ampacity Duct: 612

• 105° C Ampacity Duct: 659

• Part Number: 160-23-8052