1×50/16 mm² Tinned Copper Spiral Shield Rubber Jacket 18/30KV NTMCWÖU Medium Voltage Cable
1×50/16 mm² Tinned Copper Spiral Shield Rubber Jacket 18/30KV NTMCWÖU Medium Voltage Cable
Allowable Ampacity for 1×50/16 mm² Tinned Copper Spiral Shield Rubber Jacket 18/30KV NTMCWÖU Medium Voltage Cable: 100 Amps
About:
The 1×50/16 mm² Tinned Copper Spiral Shield Rubber Jacket 18/30KV NTMCWÖU Medium Voltage Cable is a specific type of electrical cable designed for medium voltage applications.
Also Known As:
• NTMCWÖU 18/30KV medium voltage cable
• 1×50/16 mm² rubber jacketed cable
• Tinned copper spiral shield 18/30KV cable
Application:
• Flexible medium voltage cable for connecting transformers, generators, motors and switchgear.
• Because of its high flexibility, it is particularly suitable for limited spaces where a small bending radius is required. The thermal short circuit capacity of the cable is identical to that of XLPE cables.
Standards:
• Voltage Rating: Designed for 18/30KV applications, signifying its use in medium to high voltage settings.
• Safety and Quality Standards: Likely complies with relevant national and international standards for medium voltage cables, ensuring safety, reliability, and performance.
Construction:
• Norm: DIN VDE 0250 part 813
• Conductor: Tinned fine-wire copper class 5 (DIN VDE 0295)
• Conductive layer: Conductive rubber compound
• Insulation: Rubber compound type EPR-3GI3
• Screen: Spiral of tinned copper wires
• Outer jacket: Rubber compound type 5GM3 (according to DIN VDE 0207 part 21)
Features:
• High Voltage Capacity: Capable of operating efficiently in 18/30KV power systems.
• Durability: Designed to withstand physical stresses and harsh environmental conditions.
• Electromagnetic Interference Protection: The tinned copper spiral shield minimizes the impact of EMI, which is crucial in maintaining power quality.
• Flexibility: Despite its robust construction, it maintains a level of flexibility for easier installation.
• Corrosion Resistance: The use of tinned copper enhances its resistance to corrosion, making it suitable for various environments.
Specifications:
• Cores x Cross-Section: 1×50/16 mm²
• Outer Diameter approx. in: 35.0 mm
• Min./max. Temperature for Fixed Installation: -40°C to +80°C
• Max. Conductor Temperature: +90°C
• Nominal Voltage U0/U: 6/10 (12) kV; 12/20 (24) kV; 18/30 (36) kV
• Test Voltage: acc. VDE 0250 part 813
• Mantle Color: Red
• Fire Behavior: IEC 60332-1 (EN 50265-2-1)
• Oil Resistant: EN 60811-2-1
• UV Resistant: Yes
• Weight kg/km: 1,870