2/0-3 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV
[short]
2/0-3 Teck 90 Bare Copper Aluminum Interlocked Armored Cable With Ground 1KV
Allowable Ampacity for 2/0 AWG 3C W/ Ground Teck 90 Bare Copper Aluminum Interlocked Armored Cable 1KV: 185 Amps
Applications:
Teck90 is an armored interlocked electrical cable designed for many industrial applications. It is often used in pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants, and chemical plants. The electrical wire is suitable for direct earth burial. Teck90 is used in ventilated, non-ventilated, and ladder-type cable trays. The wire is fit for service entrance above and below the ground. With HL glands, it is suitable for use in various hazardous locations. The cable is rated at 90°C wet or dry, while the minimum temperature is -40°C. The voltage rating is 1000 volts. Teck90 can serve as a cheaper alternative to installations in conduit.
Also Known As:
2/0 AWG 3C Teck90 Canadian Copper Construction Wire, 2/0 AWG 3C Teck90, 2/0 AWG 3C Teck90 Cable, 2/0 AWG 3C Teck90 Wire, 2/0 AWG 3C Teck90 Interlocked Armoured Cable, 2/0 AWG 3C TECK90 Armored Control Cable, 2/0 AWG 3C Teck90 Direct Earth Burial Wire.
Standards:
- CSA C22.2#131
- CSA C22.2 #174
- CSA C22.2 #138
- CSA C22.2 #2256
- Flame Test FT4
- HL
- AG14
- RoHS compliant
- SUN RES
- CSA AG14
Construction:
Conductors:
The conductors are round concentric lay class “B” stranded copper. A bonding ground conductor is made of stranded bare copper. The cable has an aluminum interlocked armor.
Insulation:
The wire has stranded cross-linked polyethylene (XLPE) Type RW90 insulation.
Jacket:
Black Polyvinyl Chloride (PVC) outer and inner jackets are resistant to low acid gas, sunlight, and moisture. The jackets are free of lead.
Specifications:
- AWG Size: 2/0
- Number of Conductors: 3
- Ground Wire AWG Size: 6
- Approx Diameter Inner Jacket: 1.28 inches
- Approx Armor Diameter: 1.50 inches
- Approx Diameter Outer Jacket: 1.60 inches
- Net Weight: 2.104 lbs per ft
- Amps Per Conductor: 185
Compatible with Manufacturer |
|
General Cable : | Black : 11288.0152 |
Nexans : | Black : 422428 |
Omni Cable : | Black : T32/003 |
Southwire : | Black : 561948 |
Houston Wire & Cable : | Black : HW331 20103 |
[/short]
Applications:
For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry locations. For direct earth burial. Typical applications are for power, lighting and control circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants.
Conductor:
Class B stranded, bare, soft copper
Insulation:
Cross-linked Polyethylene (XLPE)
Inner Jacket:
Black, lead-free, flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)
Outer Jacket:
Black, lead-free, flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)
Grounding Conductor:
One uninsulated stranded bare copper conductor
Assembly:
Multiple conductor cables are assembled with suitable fillers and binder tape
Armor:
Aluminum interlocked armor
Ampacity:
Based on 90°C column of Table 2 of the 2009 Canadian Electric Code, allowable ampacities for not more than three copper conductors in raceway or cable based on 30°C ambient temperature.
Standards:
The cable is certified to CSA C22.2 No. 131 Teck 90 cable and No. 174 for use in CSA Class 1, Division 1 hazardous locations (CSA HL rated) and passes the FT4 vertical tray flame test
Temperature: -40°C to 90°C