2/0-3C GND 4 AWG BC Unshielded Binder Tape MC AIA EPR PVC 5KV 133% / 8KV 100% Gaalflex MV-105 Cable
[pdf] [/pdf]
2/0-3C GND 4 AWG BC Unshielded Binder Tape MC AIA EPR PVC 5KV 133% / 8KV 100% Gaalflex MV-105 Cable
Allowable Ampacity for 2/0-3C GND 4 AWG BC Unshielded Binder Tape MC AIA EPR PVC 5KV 133% / 8KV 100% Gaalflex MV-105 Cable: 100 Amps
About:
The 2/0-3C GND 4 AWG BC Unshielded Binder Tape MC AIA EPR PVC 5KV 133% / 8KV 100% Gaalflex MV-105 Cable is a medium voltage cable designed for demanding electrical applications. It features two 4 AWG bare copper conductors with a ground wire, insulated with Ethylene Propylene Rubber (EPR) and protected by unshielded binder tape and Metal Clad Armor Interlocked Aluminum (AIA). The PVC sheath adds extra durability. Rated for 5KV at 133% and 8KV.
Also Known As:
• MV-105 cable
• medium voltage EPR cable
Application:
• Ideal for power distribution in industrial and commercial settings, especially where high voltage and current capacity are required.
• Suitable for use in both indoor and outdoor environments, including direct burial applications.
• Often used in power plants, substations, and other areas requiring medium voltage power distribution.
Standards:
• Ul Standard 1072 And Icea S-93-639 (Nema Wc 74)
• Acc. To Icea S-97-68
• Acc. To Aiec Cs-8
• Acc. To Astm B8
• Acc. To Nec
• Acc. To Epa 40 Cfr, Part 261
• Osha Approval
Construction:
• Conductor: Compressed Concentric Stranded Bare Copper Class B Acc. To Astm B8
• Inner Semi-conductive Layer: Semi-conductive Extruded Thermosetting Polymeric Layer
• Insulation: EPR Compound
• Outer Semi-conductive Layer: Semi-conductive Extruded Thermosetting Polymeric Layer
• Cores Color: Color Tapes In Each Phase (Standard: Black, Red, Blue)
• Screen: Red Copper Tape
• Earth Conductor: Compressed Concentric Stranded Bare Copper Class B Acc. To Astm B8
• Fillers: Non-hygroscopic Fillers, (If Necessary)
• Wrapping: Binder Tape
• Armouring: Aluminium Interlocked Armour (Aia)
• Outer Sheath: Yellow (Simila Ral 1021) Or Red (Similar Ral 3000) , Pvc Compound
Features:
• These Cables Are Suitable For Use In Industrial Power Circuits
• Suitable For Direct Buried, In Cunduit, Duct, Free Air, Cable Trays (Ct) And Troughs Or Raceways And Outdoor Use
• Suitable For Wet Or Dry Locations
• Approved For Class I, Div. 2 Industrial Hazardous Locations Acc. To Nec
• Suitable For 105°c Wet Or Dry Locations
• Sunlight Resistance
• Excellent Corona Resistance
• High Dielectric Strenght
• Low Moisture Absorbition
• Low Dielectric Loss
• Meeets Cold Bend Test At -35°c
• On Request With Ccw Armouring
• On Request With 3 Earth Conductors Construction
Specifications:
• Cross section AWG/MCM: 3 x 2/0 + 4
• Outer Ø Inch ±10%: 2
• Nominal voltage UL: 5 kV 133%, 8 kV 100% ,15 kV 133%
• Temperature range UL: Operating: up to +105°C ,Emergency Overload: up to +140°C , On short-Circuit: up to +250°C
• Cable weight approx. Lbs/Mft: 2696
• Part Number: 48315PYT035A2C