2/0 AWG 1C Stranded BC Tape Shield TPO Halogen-Free RG7H1M1 8.7/15KV Medium Voltage Cable
[pdf] [/pdf]
2/0 AWG 1C Stranded BC Tape Shield TPO Halogen-Free RG7H1M1 8.7/15KV Medium Voltage Cable
Allowable Ampacity for 2/0 AWG 1C Stranded BC Tape Shield TPO Halogen-Free RG7H1M1 8.7/15KV Medium Voltage Cable: 100 Amps
About:
This cable is designed for medium voltage power transmission and distribution, offering a balance of durability, safety, and performance. It is constructed to handle voltages of up to 15 kilovolts, suitable for a range of industrial, commercial, and utility applications.
Also Known As:
It might not have a specific alternative name but can be identified by its characteristics like gauge size, insulation type, and voltage rating. It’s known for its specific construction and safety features, particularly in environments where fire safety is paramount.
Application:
• Industrial Power Systems: Used in factories and plants for connecting medium voltage power sources to machinery or equipment.
• Utility Networks: Can be employed in substations or for connecting different parts of the electrical grid.
• Renewable Energy Systems: Suitable for wind farms or solar energy installations where medium voltage wiring is necessary.
• Commercial Infrastructure: Ideal for large buildings, hospitals, or campuses where medium voltage supply is needed for distribution to various sections.
Standards:
• IEC 60502-2: For medium voltage cables’ construction and performance.
• Halogen-Free Standards: Ensuring that materials used do not release toxic gases when exposed to fire.
• Electrical and Mechanical Performance Standards: Ensuring that the cable can withstand the operational stresses and electrical requirements of medium voltage applications.
Construction:
• Conductor: Stranded red copper conductor Cl. 2, acc to IEC 60228
• Inner Semi-Conductive Layer: Extruded Semi-Conducting Compound
• Insulation: Rubber type G7
• Outer Semi-Conductive Layer: Extruded Semi-Conducting Compound
• Screen: Red copper wires and one or two copper tape(s) applied helically, if necessary
• Outer Sheath: Red (RAL 3000), thermoplastic polyolefine halogen-free type M1
Features:
• According to IEC 60502-2
• Acc. to normatives DIN VDE and IEC standards
Specifications:
• No. of cores x cross section n x mm²: 1×70
• AWG no.: 2/0
• Outer-Ø ca.mm ± 10%: 28,5
• Nominal Voltage: Uo/U 1,8/3 kV, Uo/U 3,6/6 kV, Uo/U 6/10 kV, Uo/U 8,7/15 kV, Uo/U 12/20 kV, Uo/U 18/30 kV, Uo/U 26/45 kV
• Test Voltage: Uo/U 1,8/3 kV = 6 kV, Uo/U 3,6/6 kV = 11 kV, Uo/U 6/10 kV = 17 kV, Uo/U 8,7/15 kV = 24 kV, Uo/U 12/20 kV = 29 kV, Uo/U 18/30 kV = 45 kV
• Temperature range: – 5° C up to + 105° C
• Max short circuit temperature: + 250° C
• Cable Weight approx. kg/km: 1220
• Part Number: 48060SRL010M66