Sale!
,

2/0 AWG 3C Aluminum MV-105 Tape Shielded TR-XLPE 100% Insulation 115 mil 8 kV Online

Original price was: $4.99.Current price is: $2.00.

SKU: US-14932256522609 Categories: ,

2/0 AWG 3C Aluminum MV-105 Tape Shielded TR-XLPE 100% Insulation 115 mil 8 kV

[pdf] [/pdf]

2/0 AWG 3C Aluminum MV-105 Tape Shielded TR-XLPE 100% Insulation 115 mil 8 kV

Application:

 Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.
 May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.

Also Known As:

2/0 AWG MV-105 Cable, 2 Conductor Aluminum, Tape Shielded Cable, TR-XLPE Insulation, 2/0 AWG 3C PVC Jacket, 5kV-35kV Cable, 2/0 AWG 3C Aluminum MV-105, Electrical Power Cable, Multi-Conductor Cable.

Standards:

 UL 1072
 Medium Voltage Power Cables.
 ICEA S-93-639/NEMA WC74
 5 – 46 kV Shielded Power Cables
 ICEA S-97-682
 Standard for Utility Shielded. Power Cables Rated 5 – 46 kV.
 AEIC CS8
 Specification for Extruded Dielectric, Shielded Power Cables Rated 5 – 46 kV.

Features:

 UL Listed as MV-105.
 Rated as Sunlight Resistance for CT use, 1/0 AWG and larger.
 Oil Resistance I jacket.
 True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Construction:

 Conductor: : Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
 Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
 Insulation: Thermoset Three Retardant cross-linked polyethylene (TR-XLPE)
 Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
 Phase ID: Colored strings (black, red and white yarns
 Metallic Shield: Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.
 Grounding (Optional): : One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. 
 Assembly: Conductors cabled with non hygroscopic fillers, as required and binder tape.
 Jacket: Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.

Specifications:

• Size: 2/0 AWG 
• Number of Strands: 19
• Conductor Diameter (In): 0.38

• Ground Conductor Aluminum AWG:  2
• Jacket Thickness (mil): 110
• Approximate Outside Diameter (In):  1.85
• Approximate Net Weight Aluminum lb/kft: 1691

Shopping Cart
Scroll to Top