2 Cores 95 mm² W/ Earth RFOU 0.6/1KV Low Voltage Power Lighting Flame Retardant Halogen Free Cable Supply

Original price was: $4.99.Current price is: $2.00.

SKU: US-6903761764506 Categories: ,

2 Cores 95 mm² W/ Earth RFOU 0.6/1KV Low Voltage Power Lighting Flame Retardant Halogen Free Cable
2 Cores 95 mm² W/ Earth RFOU 0.6/1KV Low Voltage Power Lighting Flame Retardant Halogen Free Cable

Allowable Ampacity for 2 Cores 95 mm² W/ Earth RFOU 0.6/1KV Low Voltage Power Lighting Flame Retardant Halogen Free Cable : 100 Amps

Also Known As :

RFOU 0.6/1KV Cable, Flame Retardant Cable, Halogen Free Cable, Marine Shipyard Cable, Marine Cable, Offshore Cable, Low Voltage Power Cable

Construction :

• Conductor : Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2

• Insulation : – Code – R
                        – EPR as per IEC 60092-360
                                                  
 Cabling : – Flame Retardant & Non-hygroscopic Fillers May Be Used
                    – Suitable Tape(S) May Be Applied On The Cabled Core
                    – A Filler May Be Applied To Obtain A Circular Cable

• Inner Covering : – Code F
                                – Flame Retardant Halogen Free Thermoset Compound

• Armor : – Code O
                  – Braid Of Tinned Copper Wire (O) / Bronze Wire (B) / Galvanized Steel Wire (C)
                – Code (B,C)
                – A Suitable Separator Tape(S) May Be Applied Under/Over The Armor
 
Sheath : – Code U
               – SHF2 As Per IEC 60092-360
               – Option : NEK 606 Category A,B,C,D Mud Or Oil Resistant
               – Outer Sheath Color : Black

Core Identification :

No. Of cores Without Earth Core With Earth Core
1C Off-White or BIack
2C Off-White, BIack
3C / 2C + E Off-White, BIack, Red  Off-White, BIack, G/Y
4C / 3C + E Off-White, BIack, Red, BIue Off-White, BIack, Red, G/Y
5C / 4C + E BIack No. On White InsuIation Off-White, BIack, Red, BIue, G/Y
6C and over BIack No. On White InsuIation BIack No. On white InsuIation, G/Y



Application Standards :

• Design Guide : NEK-606 & IEC 60092-353
• Flame Retardant :
IEC 60332-1 & IEC 60332-3 Category A
• Halogen Content :
IEC 60754-1, 0.5%
• Cold Bend / Impact :
CSA C22.2 No. 2556 Or IEC 60092-350 Annex.E Method 1 (-40ºC/-35ºC)
• Mud / Oil Resistant :
NEK 606 (Category A,B,C,D)
• Smoke Light Transmittance :
IEC 61034, 60%
• Sunlight (UV) Resistant :
UL 1581

Specification :

• No of Cores : 2 Core
• No of Earth : 1
• Conductor Nominal Area :
95 mm²
• Earth Conductor Nominal Area : 50 mm²
• Conductor Min. No. Of Wires :
19 EA
• Earth Conductor Min. No. Of Wires : 19 EA
• Conductor Max.Over All Dia :
12.9 mm
• Earth Conductor Max.Over All Dia : 9.1 mm
• Thickness of Insulation :
1.6 mm
• Earth Thickness of Insulation : 1.4 mm
• Thickness of Inner Covering :
1.2 mm
• Nominal Dia. Inner Covering :
34.9 mm
• Dia. of Wire for Armour :
 0.4 mm
• Thickness of Sheath :
2.3 mm
• Overall Diameter Nominal :
41.4 mm
• Overall Diameter Tolerance:
2.0 ±mm
• Conductor Resistance (at 20°C) (Max.) :
0.195 Ω/km
• Earth Conductor Resistance (at 20°C) (Max.) : 0.391 Ω/km
• Insulation Resistance (at 20°C) (Min.) :
370 MΩ-km
• Test Voltage :
3,500 V/5min
• Cable Weight :
2.702 Lbs/Ft