Sale!
,

20 AWG 20T PLTC Instrumentation Tray Cable Individual and Overall Shield PVC/CPE 300V Hot on Sale

Original price was: $4.99.Current price is: $2.00.

SKU: US-14606277673329 Categories: ,

20 AWG 20T PLTC Instrumentation Tray Cable Individual and Overall Shield PVC/CPE 300V

[pdf] [/pdf]

20 AWG 20T PLTC Instrumentation Tray Cable Individual and Overall Shield PVC/CPE 300V

Application:

• The cables can be used in raceways or, when provided with a messenger, for aerial application. When increased mechanical, chemical, or environmental protection is required, a hermetically sealed aluminum tape or copper tape armor with an additional PCV or CPE jacket can be provided.
• Cable is suitable for use in Class I Division II hazardous locations.
• Cable is UL approved for Sunlight Resistant and Direct Burial Applications.
• Recommended Operating Voltage: 300V

Scope:

 These Instrumentation Cables are UL listed under Article 725 of the NEC and are suitable for cable tray use in Class 1, Division 2 hazardous locations. The cable can be  used in wet or dry locations and up to conductor temperatures of 105°C.
 The individually shielded pairs and triads are completely isolated from each other by use of a polyester tape. This shielding assures maximum protection from crosstalk and common mode interference. An overall shield provides additional protection.
 The flame properties meet or exceed the requirements of both the UL 70,000 BTU vertical tray flame test and the comparable IEEE-383 flame test. A 210,000 BTU rating is also available upon request.

Also Known As:

20 AWG 20T PLTC Cable, Instrumentation Cable, 20 AWG 20T 300V PLTC Tray Cable, 20 AWG 20T PVC/CPE 300V Instrumentation Tray Cable, PVC/CPE  Instrument Cable, PLTC Tray Cable, 20 AWG 20T PVC/CPE 300V Individual and Overall Shield Instrumentation Tray, PVC/CPE Cable.

Construction:

Class B, stranded per ASTM B-3 and ASTM B-8

Primary Insulation:

105°C rated PVC
Thickness: .015″ nominal thickness

Shielding:

Each triad with individual drain wire is shielded with aluminum /polyester tape.
All are isolated with an additional polyester tape. Overall shield is helically
applied with 100% coverage with a tinned copper drain wire.

Overall Jacket:

PVC (105°C rated) or CPE (90°C rated)
Ripcord is applied under the jacket to facilitate stripping.

Standards:

UL listed as type PLTC & CL3 per UL standard 13 as type ITC per UL standard 2250.
Meets IEEE 1202 flame test.
All materials used in the manufacture of this cable are RoHS compliant.

Specifications:

• AWG: 20
• No. of Triads: 20 
• Nominal Jacket Thickness (In): .062 
• Nominal Outside Diameter (In): .849
• Pulling Tension (Pounds): 612
 Nominal Weight 1000 FT (Pounds): 485