Sale!
,

20 Triad 1.0 mm² JIS C 3410 250V RCOP(OS) Shipboard Flame Retardant Instrumentation Cable Online

Original price was: $4.99.Current price is: $2.00.

SKU: US-6686700601498 Categories: ,

20 Triad 1.0 mm² JIS C 3410 250V RCOP(OS) Shipboard Flame Retardant Instrumentation Cable

20 Triad 1.0 mm² JIS C 3410 250V RCOP(OS) Shipboard Flame Retardant Instrumentation Cable

Allowable Ampacity For 20 Triad 1.0 mm² JIS C 3410 250V RCOP(OS) Shipboard Flame Retardant Instrumentation Cable : 100 Amps

Application Standard :

  • • Design Guide : IEC 60092-350 & IEC60092-376
  • • Flame Retardant : IEC60332-1
                                    : IEC 60332-3 Category A (FA-Cables Only)
  • • Cold Bend/Impact : CSA 22.2 No. 03 (-40℃/-35℃) (Cold Type Only)
  • • Max. Rated Conductor Temperature : 90℃


Also Known As :

Shipboard Cable, JIS C 3410 Cable, RCOP(OS) Cable, Asian Shipyard Cable, Flame Retardant Cable, Annealed Copper Wire, Instrumentation Cable, Japenese Industrial Cable, Marine Shipyard Cable

Construction :

Conductor :

  • • Stranded Tinned Annealed Copper Wires As Per IEC 60228, Class 2


Insulation :

  • • Code : R
  • • EPR As Per IEC 60092-351


Twisting :

  • • Two/Three Insulated Cores Shall Be Twisted Together To Form A Pair/Triad


Cabling :

  • • Twisted Pairs/Triads Shall Be Cabled
  • • Flame Retardant & Non-Hygroscopic Fillers May Be Used
  • • Suitable Tape(s) May Be Applied On The Cabled Core
  • • A Filler May Be Applied To Obtain A Circular Cable


Collective Screen :

  • • Code : (OS)
  • • AL/PS Tape + Tinned Copper Drain Wire (0.75mm2)
  • • A Suitable Tape May Be Applied On The Collective Screen


Inner Sheath :

  • • Code : C
  • • SE1 As Per IEC60092-359


Armour :

  • • Code : O
  • • Braid Of Plain Annealed Copper Wires
  • • Coverage Density Is Minimum 90%


Outer Sheath :

  • • Code : P
  • • ST2 (PVC) As Per IEC 60092-359
  • • Outer Sheath Color : Grey (For Non-IS Type) Or Blue (For IS Type)


Core Identification :

  • • Printed Pair/Triad Number And Alphabet Letter On The White Insulation
  • • ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B)
  • • 2T : (1A, 1B, 1C), (2A, 2B, 2C)


Specification :

  • • No. Of Units : 20T
  • • Conductor Nominal Area : 1.0 mm²
  • • Conductor Strand : 7/0.43 No./mm
  • • Conductor Dia. : 1.29 mm
  • • Nominal Dia. Inner Sheath : 30.3 mm
  • • Overall Diameter Nominal : 35.5 mm
  • • Overall Diameter Tolerance : 1.7 ±mm
  • • Conductor Resistance (at 20°C) (Max) : 19.3 Ω/km
  • • Insulation Resistance (at 20°C) (Min) : 20 Ω/km
  • • Cable Weight : 1.3969 lbs
Shopping Cart