Sale!
,

250′ 2/0-2/0-2/0-1 Copper SER Service Entrance Cable on Sale

Original price was: $4,372.50.Current price is: $299.99.

SKU: US-8102136807578 Categories: ,

250′ 2/0-2/0-2/0-1 Copper SER Service Entrance Cable

[pdf] [/pdf]

[short]

2/0-2/0-2/0-1 Copper SER Service Entrance Cable

Allowable Ampacity at 60° C: 145

Allowable Ampacity at 75° C: 175

Allowable Ampacity at 90° C: 195

Applications:

SER is a service entrance cable with a reinforcement tape used in all instances where service entrance cables are allowed. The electrical cable is most often used to connect the service drop to the meter base and from the meter base to the distribution panelboard. SER is suitable for dry locations, with temperatures not exceeding 90°C. The voltage rating  of the electrical cable is 600 volts.

Also Known As:

2/0-2/0-2/0-1 Copper SER Service Entrance Cable, 2/0-2/0-2/0-1 Reinforcement Tape Service Entrance Cable, 2/0-2/0-2/0-1 SER Cable, 2/0-2/0-2/0-1 SER Service Cable, 2/0-2/0-2/0-1 Copper Service Cable, 2/0-2/0-2/0-1 Round Service Entrance Cable.

Standards:

  • ASTM- All applicable standards
  • UL Standard 44 for XHHW-2 conductors
  • UL Standard 83 for THHN/THWN conductors
  • UL Standard 854
  • Federal Specification A-A-59544
  • National Electrical Code, NFPA 70. 2011 Edition
  • RoHS/ REACH

Construction:

Conductor:

The cable is equipped with annealed soft copper conductors. It typically has three-phase conductors with a bare neutral.

Insulation:

The cable has cross-linked polyethylene type XHHW-2 insulation.

Jacket:

SE cable is jacketed with gray sunlight-resistant polyvinyl chloride (PVC). This dielectrically strong insulation is resistant to corrosion, abrasion, chemicals, and mechanical impact.

Specifications:

  • Size AWG: 2/0-2/0-2/0-1
  • Weight per 1,000 ft: 1713 lbs
  • Outside Diameter: 1342 mils
  • Conductors: Annealed Soft Copper
  • Stranding: Phase & Neutral Conductors: 19
  • Stranding: Equipment Ground Conductor: 19
  • Insulation: XLPE
  • Jacket: PVC

Compatible with Manufacturer

Priority Wire & Cable : 2/0-03CUG-R-SER
Omni Cable : 2/0-03GSERCU
Southwire : 27083501

[/short]

APPLICATIONS

Type SE, service entrance cable is primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard; however, the cable may be used in all applications where Type SE cable is permitted. SER may be used in wet or dry locations at temperatures not to exceed 90°C. Voltage rating is 600 volts. 

SPECIFICATIONS

  • ASTM- All applicable standards
  • UL Standard 44 for XHHW-2 conductors
  • UL Standard 83 for THHN/THWN conductors
  • UL Standard 854
  • Federal Specification A-A-59544
  • National Electrical Code, NFPA 70. 2011 Edition
  • RoHS/ REACH

CONSTRUCTION

Type cable is constructed with sunlight resistant Type XHHW-2 conductors or Type THHN/THWN conductors. Copper conductors are annealed (soft) copper. Cable assembly plus reinforcement tape are jacketed with sunlight resistant gray polyvinyl chloride (PVC). Available as 1 conductor with a concentric ground, 2 conductor with a round or concentric ground, or 3 conductor with a bare ground. SE cable is jacketed with gray sunlight resistant polyvinyl chloride (PVC).

 

Shopping Cart