4 ALUMINUM RHH/RHW-2 XLP USE-2 DIRECT BURIAL

Allowable Ampacity for 4 ALUMINUM RHH/RHW-2 XLP USE-2 DIRECT BURIAL: 65 Amps

Applications:

USE-2 cables are power distribution cables for service entrance below ground and direct burial, as well as raceways. The electrical cable is approved according to the National Electric Code, except for the use in cable trays. The maximum operating temperature for this electrical cable is 90°C in wet and dry locations. The voltage rating is 600 volts.

Also Known As:

4 aluminum rhh wire, 4 aluminum rhw cable, 4 aluminum bury cable, direct burial electrical cable, direct burial power cable, direct burial service entrance cable.

Standards:

  • UL 44
  • UL 854
  • NEMA WC 70/ICEA S-95-658
  • Requirements of the National Electrical Code
  • ASTM B800, B801, B836
  • Sunlight resistant
  • Oil Resistant PRI/PRII
  • Gas and Oil Res GRI/GRII
  • RUS ACCEPTED

Construction

Conductors:

Compact bare 8000 series aluminum, with Class B stranding per ASTM. 

Insulation:

Abrasion, heat and moisture resistant cross-linked polyethylene insulation (XLP)

Specifications:

  • Gauge: 4

  • Stranding: 7

  • Conductor Diameter Inches: 0.213

  • Insulation Thickness Inches: 0.080

  • O.D. Inches: 0.370

  • New Weight lb/1000FT: 236 lbs

  • Ampacity at 30°C: 65 Amps

Compatible with Manufacturer

Houston item : Black : HW003A00401
Black : 4-01XLPUSEBLACKAL
Priority Wire & Cable : Black : 4-01XL-USE-2-ALUM
Southwire : Black : 27280701

[/short]

Application:

USE-2 cables are primarily used for power distribution, in raceways in accordance with National Electrical Code, except that the cable is not rated for use in cable tray. USE-2 is approved for direct burial and for service entrance below ground. USE-2 cables may be used in wet or dry locations, with ambient temperatures not exceeding 90°C. Voltage rating for USE-2 cable is 600V.

Conductors:

USE-2 conductor is a soft drawn bare 8000 series aluminum, with Class B stranding per ASTM

Insulation:

USE-2 has abrasion, heat and moisture resistant cross-linked polyethylene insulation XLPE

Standards:

  • USE-2 meets or exceeds the following standards 
  • UL 44 
  • Requirements of the National Electrical Code 
  • ASTM standards B 800, B 801 
  • Sunlight resistant 
  • RUS ACCEPTED
Color

Black, Green