250 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

[pdf] [/pdf]

250 MCM 1C Non-Shielded EPR 133% Hypalon CSPE Jacket MV-105 Cable 5KV

Description:

A. Where NEC jurisdiction applies; as 5,000 volt nonshielded power cable. Type MV-105, for use at conductor temperatures not exceeding 105°C in wet or dry locations. Cables meet requirments of Article 310-6 of the National Electrical Code.

B. For other applications, as nonshielded power cables for use at 5000 volts 100% insulation level (grounded neutral) and 133% insulation level (ungrounded neutral) under the following conditions: (a) Single conductors mounted on insulation in free air in indoor or outdoor locations.

Circuit voltages are 2400 volts, 4160 volts and 4800 volts. (b) Random lay singles in metal conduit and nonmetallic conduit in dry locations at circuit voltage of 2400 volts, 4160 volts and 4800 volts, and in damp or wet locations at circuit voltages of 2400 volts and 4160 volts.

(c) Triplexed singles in metal conduit and nonmetallic conduit in damp or wet locations at circuit voltage of 4800 volts.

(d) Single conductors or triplexed singles in cable tray, spaced block supports or in messenger supported rings in dry, damp or wet locations at circuit voltages of 2400 volts and 4160 volts. 

(e) Triplexed singles in cable tray, spaced block supports or in messenger supported rings in damp or wet locations at circuit voltage of 4800 volts.

(f) Single conductors or triplexed singles, aerially, field-spun to grounded messenger in dry, damp or wet locations at circuit voltages of 2400 volts, 4160 volts, and 4800 volts.

Also Known As:

250 MCM Hypalon Jacket Cable, 250 MCM MV Cable, 250 MCM Medium Voltage Cable, 250 MCM CSPE Cable, 250 MCM MV-105 Cable, 250 MCM MV 5K Cable.

Application: 

Listed by Underwriters Laboratories as 5,000 volt nonshielded cable, Type MV-105 per UL Standard 1072
Conforms to ICEA Pub. No. 539-693 and NEMA Pub. No. WC4 for Ethylene-propylene rubber-insulated Wire and Cable
• Sizes 1/0 and larger pass UL and IEEE Standard 383 ribbon burner flame test and are UL listed for CT use
• Construction: Annealed tinned copper conductor, extruded conductor shield, EPR insulation, discharge and moisture resistant Hypalon jacket, surface printed

Specification: 

• Gauge Size: 250 
• No Of Strands: 37
• Insulation Thickness: 0.140 Inch
• Jacket Thickness: 0.110 Inch
• Overall Diameter: 1.14 inch
• Net Weight: 1185 lbs/mft
• Part No: P10O2