Sale!
,

250 MCM 3C Aluminum MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV Online now

Original price was: $4.99.Current price is: $2.00.

SKU: US-14930056839537 Categories: ,

250 MCM 3C Aluminum MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV

[pdf] [/pdf]

250 MCM 3C Aluminum MV-105 Tape Shielded EPR Insulated CPE Jacket 5 kV

Application:

 Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.
 May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.

Also Known As:

250 MCM 3C MV-105 Cable, 3 Conductor Aluminum, Tape Shielded Cable, EPR Insulation, 250 MCM 3C 3C CPE Jacket, 5kV-25kV Cable, 250 MCM 3C 3C Aluminum MV-105, Electrical Power Cable, Multi-Conductor Cable.

Standards:

 UL 1072
 Medium Voltage Power Cables.
 ICEA S-93-639/NEMA WC74
 5 kV – 46 kV Shielded Power Cables.
 ICEA S-97-682
 Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.
 AEIC CS8
 Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.

Features:

 UL Listed as MV-105.
 True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.
 Rated as Sunlight Resistance for CT use for all cable sizes.

Construction:

 Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
 Conductor Shield: : Semi conducting cross-linked polyethylene (XLPE).
 Insulation: Thermoset ethylene propylene rubber (EPR)
 Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
 Phase ID: Colored strings (black, red and White yarns.)
 Metallic Shield: Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.
 Grounding (Optional): One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. 
 Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
 Jacket: Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. 

Specifications:

• Size: 250 MCM
• Number of Strands: 37
• Conductor Diameter (In): 0.52
• Ground Conductor Copper AWG: 1
• Jacket Thickness (mil): 110
• Approximate Outside Diameter (In): 2.13
• Approximate Net Weight Aluminum lb/kft: 2411