250 Type UL MV90 EPR Insulation PVC Jacket Shielded 100% Insulation Copper Power Cable 15kV
[short]
250 Type UL MV90 EPR Insulation PVC Jacket Shielded 100% Insulation Copper Power Cable 15kV
Applications:
The mv90 copper cable is an electrical wire used for power circuits up to 15,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.
Also Known As:
250 mcm medium voltage power cables, 250 mv power cable, 250 mv90 cable, 250 mv90, 250 mv 90 air compressor, 250 epr power cable, 250 mcm mv power cable, 250 mcm mv90 cable, 250 mcm mv90, 250 mcm mv 90 air compressor, 250 mcm epr power cable.
Standards:
- ICEA S-93-639
- NEMA WC74
- AEIC CS8
Construction
Conductors:
The MV power cable conductor is made of copper with a semi-conducting conductor shield: soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed), or ASTM B-496 (compact).
Insulation:
A strong and enduring ethylene-propylene rubber (EPR) is used as the insulation system. The good thing about this insulation is how friendly it is to human hands since it is a rubber, a material that tends to be soft but guarantees profound and reliable safety wires. This insulation is also environmentally friendly, it doesn’t have some toxins which can cause harm to human, animals, and plants health.
Jacket:
Reinforced insulation is provided by a PVC jacket, which is sunlight-resistant, per ICEA S-97-682 and UL Standard 1072.
Specifications:
- AWG Size: 250
- Number of Strands: 37
- Overall Diameter (inches): 1.12
- Net Weight (Lbs/1000FT): 1232
Compatible with Manufacturer |
|
Omni Cable : | MVEH325001 |
Houston Wire & Cable : | HW20725001 |
[/short]
Power Cable –
15KV UL Type MV-90, 90°C Single Conductor, Sheilded,
XLP Insulation, PVC Jacket
100% Insulation Level, Copper Conductor
Application:
Appropriate for all situations of corrosive environments in power circuits up to 15,000V when installed in open air, conduit, and duct, cable tray when CT rated, in wet and dry locations. Main uses are for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code permitted for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.
Conductor:
Has a semi-conducting conductor shield, with a compacted soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496.
Insulation:
Ethylene propylene rubber (EPR) per ICEA S-97-682.
Shield:
Shielding wires meet ICEA standards.
Jacket:
Sunlight-resistant PVC per ICEA S-97-682 and UL Standard 1072.