Sale!
,

250 MV105 OR MV90 Non-Shielded XLP 133% Insulation Copper Cable 5KV Fashion

Original price was: $4.99.Current price is: $2.00.

SKU: US-3543487086692 Categories: ,

250 MV105 OR MV90 Non-Shielded XLP 133% Insulation Copper Cable 5KV

[short]

250 MV105 OR MV90 Non-Shielded XLP 133% Insulation Copper Cable 5KV

Applications:

The mv105 or mv90 copper cable is an electrical wire used for power circuits up to 5,000 Volts when fixed in open air, conduit, or duct; in applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations, and generating stations. The National Electric Code accepts this electrical cable for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.

Also Known As:

250 mcm medium voltage power cables, 250 mv power cable, 250 mv105 cable, 250 mv90, 250 mv105, 250 mcm mv power cable, 250 mcm mv105 cable, 250 mcm mv90, 250 mcm mv105.

Standards:

  • ICEA S-96-659
  • UL Standard 1072
  • NEMA WC 71

Construction

Conductors:

Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact), with a semi-conducting conductor shield.

Insulation:

It has cross-linked polyethylene (XLP) insulation. The conductors are normally cabled together with XLP insulated aluminum ground or bare copper ground and covered with reinforced binder tape. XLP insulation is tough and resistant to impact, abrasion, chemicals, acids, oils, industrial solvents, and changes in weather.

Specifications:

  • AWG Size: 250
  • Number of strands: 37
  • Overall diameter (inches): 0.83
  • Net Weight (lb/1000FT): 890 lbs

Compatible with Manufacturer

Houston Wire & Cable : HW20025001
Priority Wire & Cable : 250-012.4KVNSEP

[/short]

Applications:

Uses for such as power circuits up to 5000 Volts when fixed in open air, conduit or duct.  In applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code accepted for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductor:

Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact), with a semi-conducting conductor shield.

Insulation:

Cross-linked polyethylene (XLP) per ICEA regulations.

Additional Standards: 
  • ICEA S-96-659
  • UL Standard 1072
  • NEMA WC 71
Shopping Cart
Scroll to Top